GR6FNA218 5kV High Voltage Relay 5 kv relay  
 No Load Switching
 RoHS Compliant, date code 0701 and later
 

GR6FNA HIGH VOLTAGE RELAY
 
 
 

 

 

 

High Voltage Relay Features
  RF efficient design offers high power handling in a small package
  High voltage solder connections provide additional external isolation from PC boards
  Mechanical life of 100 million operations is ideal for high speed, long life RF switching
  Vacuum dielectric offers low stable contact resistance
High Voltage Relay Specifications
 Contact & Relay Ratings Units GR6FNA218
 Contact Form A
 Contact Arrangement SPST-NO
 Voltage Ratings
      Between Contacts kV Peak 5
      Contacts to Coil kV Peak 5
 Current Carry , Max.
      @ DC Amps 8
      @ 30 Mhz Amps 6
 Contact Resistance Ohms

0.050

 Capacitance
      Across Open Contacts pF 0.6
      Closed Contacts to Ground pF 4
 Initial Insulation Resistance GigaOhms 10
 Operate Timeasteriks ms 3
 Release Timeasteriks ms 1
 Mechanical Life cycles 100 million
 Weight, Nominal g (oz) 24 (0.85)
 Vibration, Operating, Sine(10-500 Hz  Peak) G's 20
 Shock, Operating, 1/2 Sine 11ms (Peak) G's 100
 Temperature Range
      Operating °C -40 to +85
      Storage °C -55 to +125

 

High Voltage Relays - Coil Ratings
Units GR6FNA218
 Volts, Nominal Vdc 12
 Voltage, Max. Vdc 15
 Pickup, Max. Vdc 8
 Dropout, Max. Vdc 2
 Coil Resistance Ohms 480
 
asteriks Operate and release times are with external diode suppression, @ 25°C.

 
For more information, refer to
Relay User Instructions

 

04/03/08

 

 

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  