GR5MTA 15kV Make & Break Load Switching Relay 15 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0701 and later
 

GR5MTA HIGH VOLTAGE RELAY

GR5 MTA make and break switching

High Voltage Relay Features
  Most cost effective choice for many 15kV applications
  Vacuum dielectric offers low stable contact resistance
  Durable tungsten coated contacts for hot load switchingasteriks
  Coil choices of 5, 12 or 24Vdc accommodate virtually any drive circuit
asteriks See load chart on this page.
Consult factory for loads not listed.
High Voltage Relay Specifications
 Contact & Relay Ratings Units GR5MTA
 Contact Form A
 Contact Arrangement SPST-NO
 Load Switching see chart below
 Voltage Ratings between Contacts kVPeak 15
 Current Carry @ DC Amps 5
 Contact Resistance Ohms 0.250
 Capacitance
      Across Open Contacts pF 1
      Closed Contacts to Ground pF 8
 Initial Insulation Resistance GigaOhms 10
 Operate Time ms 3
 Release Time ms 2
 Mechanical Life/ Rated Load cycles 100 million
 Weight, Nominal g (oz) 28 (1)
 Vibration, Operating, Sine(10-500 Hz  Peak) G's 20
 Shock, Operating, 1/2 Sine 11ms (Peak) G's 100
 Temperature Range
      Operating °C -20 to +70
      Storage °C -35 to +125
High Voltage Relays - Coil Ratings
 Nominal, Volts dc 5 12 24
 Pick-up, Volts dc, Max. 3.7 9 20
 Drop-Out, Volts dc 0.5 1.25 4
 Coil Resistance
 (Ohms  ±10%)
16 95 350
 
For more information, refer to
Relay User Instructions

 
GR5MT A 3 3 5
 Contact Form
 A = SPST-NO
 Coil Voltage 
 1 = 5 Vdc
 2 = 12 Vdc
 3 = 24 Vdc
 High Voltage Connections
 3 = PC Pins
 Mounting
 5 = PC Pins
Load Switching Life in cycles
Voltage Current
110 Vac 0.5 Amps 1,000,000
120 Vac 1.0 Amps 200,000
1000 Vac 200 mAmps 100,000
5000 Vac 83 mAmps 1,000