Most cost effective choice
for many 15kV applications |
 |
 |
|
Vacuum dielectric offers low stable
contact resistance |
 |
 |
|
Durable tungsten coated contacts for
hot load switching |
 |
 |
|
Coil choices of 5, 12 or 24Vdc accommodate
virtually any drive circuit |
|
 |
See load chart on this page.
Consult factory for loads not listed. |
|
 |
| Contact
& Relay Ratings |
Units |
GR5MTA |
| Contact Form |
 |
A |
| Contact
Arrangement |
 |
SPST-NO |
| Load Switching |
 |
see chart below |
| Voltage
Ratings between Contacts |
kVPeak |
15 |
| Current Carry @ DC |
Amps |
5 |
| Contact
Resistance |
Ohms |
0.250 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
1 |
| Closed
Contacts to Ground |
pF |
8 |
| Initial
Insulation Resistance |
GigaOhms |
10 |
| Operate Time |
ms |
3 |
| Release
Time |
ms |
2 |
| Mechanical Life/
Rated Load |
cycles |
100 million |
| Weight,
Nominal |
g (oz) |
28 (1) |
| Vibration, Operating,
Sine(10-500 Hz Peak) |
G's |
20 |
| Shock,
Operating, 1/2 Sine 11ms (Peak) |
G's |
100 |
| Temperature Range |
 |
 |
| Operating |
°C |
-20 to +70 |
| Storage |
°C |
-35 to +125 |
|
 |
| Nominal,
Volts dc |
5 |
12 |
24 |
| Pick-up,
Volts dc, Max. |
3.7 |
9 |
20 |
| Drop-Out,
Volts dc |
0.5 |
1.25 |
4 |
Coil
Resistance
(Ohms ±10%) |
16 |
95 |
350 |
|
For more information, refer to
Relay User Instructions
| GR5MT |
A |
3 |
3 |
5 |
| |
 |
 |
 |
Coil
Voltage 1
= 5 Vdc 2
= 12 Vdc 3
= 24 Vdc |
|
High
Voltage Connections 3
= PC Pins |
|
| |
|
| Load
Switching |
Life
in cycles |
| Voltage |
Current |
| 110 Vac |
0.5 Amps |
1,000,000 |
| 120 Vac |
1.0 Amps |
200,000 |
| 1000 Vac |
200 mAmps |
100,000 |
| 5000 Vac |
83 mAmps |
1,000 |
04/03/08
|
|