GR3BJA335 1.5kV High Voltage Relay 1.5 kv relay  
 No Load Switching
 RoHS Compliant, date code 0701 and later
 
GR3BJA RELAYS
GR3 BJA No Load Switching
High Voltage Relay Features
 GR3BJA335
  RF efficient design offers high power handling in a small package
  High resistance coil means low current requirement for driver circuits
  RF screen helps assure interference free operation when relays are mounted side by side
  PC pins provide the ultimate choice for connectivity and ease of mounting
  Vacuum dielectric offers low stable contact resistance
High Voltage Relay Specifications
 Contact & Relay Ratings Units GR3BJA335
 Contact Form A
 Contact Arrangement SPST-NO
 Voltage Ratings
      Between Contacts kV Peak 1.5
      Contacts to Coil kV Peak 1.5
      Contacts to Screen kV Peak 1.5
      Coil to Screen kV Peak .5
 Current Carry , Max.
      @ DC Amps 3
      @ 30 Mhz Amps 3
 Contact Resistance Ohms

0.050

 Capacitance
      Across Open Contacts pF 0.3
      Closed Contacts to Ground pF 4
 Initial Insulation Resistance GigaOhms 10
 Operate Timeasteriks ms 0.8
 Release Timeasteriks ms 0.5
 Mechanical Life cycles 100 million
 Weight, Nominal g (oz) 7 (0.24)
 Vibration, Operating, Sine(10-2000 Hz  Peak) G's 30
 Shock, Operating, 1/2 Sine 11ms (Peak) G's 100
 Temperature Range
      Operating °C -20 to +70
      Storage °C -35 to +110

 
High Voltage Relays - Coil Ratings
Units GR3BJA335
 Volts, Nominal Vdc 28
 Voltage, Max. Vdc 33
 Pickup, Max. Vdc 19
 Dropout, Max. Vdc 2
 Coil Resistance Ohms 2500
 RF Screen, Inner Pin # S1
 
asteriks Operate and release times are with external diode suppression, @ 25°C.

 
For more information, refer to
Relay User Instructions

 

04/03/08

 

 

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  
fx +(805) 684-8402 -   - www.gigavac.com - ©Copyright 2003-2008 GIGAVAC, LLC.