GR2DNA 3kV High Voltage Relay 3 kv relay  
 No Load Switching
 RoHS Compliant, date code 0701 and later
 

GR2DNA HIGH VOLTAGE RELAY

 

 

 

High Voltage Relay Features
  RF efficient design offers high power handling in a small package
  PC pins provide the ultimate choice for connectivity and ease of mounting
  Vacuum dielectric offers low stable contact resistance
  Coil choices of 5, 12 or 24Vdc accommodate virtually any drive circuit
High Voltage Relay Specifications
 Contact & Relay Ratings Units GR2DNA
 Contact Form A
 Contact Arrangement SPST-NO
 Voltage Ratings between Contacts kV Peak 3
 Current Carry @ DC Amps 2
 Contact Resistance Ohms 0.100
 Capacitance
      Across Open Contacts pF 1.5
      Closed Contacts to Ground pF 6
 Initial Insulation Resistance GigaOhms 10
 Operate Timeasteriks ms 1
 Release Timeasteriks ms 1
 Mechanical Life/ Rated Load cycles 100 million
 Weight, Nominal g (oz) 5 (0.18)
 Vibration, Operating, Sine(10-2000 Hz  Peak) G's 30
 Shock, Operating, 1/2 Sine 11ms (Peak) G's 100
 Temperature Range
      Operating °C -20 to +70
      Storage °C -35 to +110

 
 
 
 

 

High Voltage Relays - Coil Ratings
 Nominal, Volts dc 5 12 24
 Pick-up, Volts dc, Max. 3.7 9 20
 Drop-Out, Volts dc .5 1.25 3
 Coil Resistance
 (Ohms  ±10%)
140 600 1,000
 
For more information, refer to
Relay User Instructions

 
GR2DNA A 3 3 5
 Contact Form
 A = SPST-NO
 Coil Voltage 
 1 = 5 Vdc
 2 = 12 Vdc
 3 = 24 Vdc
 High Voltage Connections
 3 = Solder Connection
 Mounting
 5 = PC Pins
 
asteriks Operation and release times are with external diode suppression, @ 25°C.

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  
fx +(805) 684-8402 -   - www.gigavac.com - ©Copyright 2003-2008 GIGAVAC, LLC.