| GH 3.5kV SERIES |
 |
 |
|
Low profile is extremely
space efficient, 3.5kV rating |
 |
 |
|
Easy to mount threaded base with jam
nut |
 |
 |
|
User interchangeable coils provide for
driver versatility |
 |
 |
|
Meets or exceeds standards set in MIL-R-83725 |
 |
| GH1 - No Load Switching |
 |
 |
|
Low, stable contact resistance
minimizes loss in RF circuits |
 |
 |
|
High carry current, 25Adc continuous,
in a small package |
 |
GH3 - Make & Break
Load
Switching |
 |
 |
|
Durable tungsten contacts for hot load
switching |
 |
 |
|
Vacuum dielectric for effective arc
quenching when opening under load |
 |
GH5 - Make Only Load
Switching
|
 |
 |
|
Excellent for capacitive discharge and
safety dump switch applications |
 |
 |
|
Additional isolation capabilities in
many applications (consult factory) |
|
 |
Consult factory for load switching
apps.
|
|
 |
| Contact
& Relay Ratings |
Units |
GH1 |
GH3 |
GH5 |
| Contact
Form |
 |
C |
C |
C |
| Contact Arrangement |
 |
SPDT |
SPDT |
SPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage
Max., dc or 60Hz) |
kV
Peak |
5 |
5 |
5 |
| Voltage, Operating
Max., Contacts & to Base (15 µA Leakage
Max.) |
 |
 |
 |
 |
| dc
or 60 Hz |
kV Peak |
3.5 |
3.5 |
3.5 |
| 2.5
MHz |
kV Peak |
2.5 |
- |
- |
| 16
MHz |
kV Peak |
2 |
- |
- |
| 32
MHz |
kV Peak |
1.5 |
- |
- |
| Current,
Continuous Carry Max |
 |
 |
 |
 |
| dc
or 60 Hz |
Amps |
25 |
18 |
8 |
| 2.5
MHz |
Amps |
14 |
- |
- |
| 16
MHz |
Amps |
9 |
- |
- |
| 32
MHz |
Amps |
7 |
- |
- |
| Coil
Hi-Pot (V RMS, 60 Hz) |
V |
500 |
500 |
500 |
| Capacitance |
 |
 |
 |
 |
| Across
Open Contacts |
pF |
2 |
- |
- |
| Contacts
to Ground |
pF |
2.5 |
- |
- |
| Resistance, Contact
Max @ 1A, 28Vdc |
ohms |
0.01 |
0.02 |
0.50 |
| Operate
Time |
ms |
6 |
6 |
6 |
| Release Time |
ms |
6 |
6 |
6 |
| Life,
Mechanical |
cycles |
2
million |
2
million |
1
million |
| Weight, Nominal |
g (oz) |
28 (1) |
28 (1) |
28 (1) |
| Vibration,
Operating, Sine (55-2000 Hz Peak) |
G's |
10 |
10 |
10 |
| Shock, Operating,
1/2 Sine 11ms (Peak) |
G's |
50 |
50 |
50 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
-55 to +125 |
-55 to +125 |
 |
 |
| Nominal,
Volts dc |
12 |
26.5 |
115 |
| Pick-up,
Volts dc, Max. |
8 |
16 |
80 |
| Drop-Out, Volts dc |
.5
- 5 |
1 -
10 |
5 -
50 |
Coil
Resistance
(Ohms ±10%) |
80 |
335 |
6000 |
Ratings listed are for 25°C, sea level conditions |
For more information, refer to
Relay User Instructions
| GH |
1 |
- 12Vdc |
 |
 |
| |
Coil
Voltage
Blank = 26.5Vdc 12Vdc
= 12Vdc 115Vdc
= 115Vdc |
|
|
 |
Order the relay with the coil voltage
in the part number as shown above. The coil voltage will appear
on the coil plate near the coil terminals rather than in the
P/N on the relay. |
04/03/08 |
|