G8L 15kV Latching Make & Break Load Switching Relay 15 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0701 and later
 
G8L LATCHING HIGH VOLTAGE RELAY

G8L HIGH VOLTAGE RELAY
 



G 8L Latching
 
 

High Voltage Relay Features
  text
  Durable tungsten contacts for hot load switchingasteriks
  Vacuum dielectric for effective arc quenching when opening under loadasteriks
  Two mounting styles available, flange or through panel with jam nut.
  Solder or threaded high voltage connections help make installation easy.
  User interchangeable coils provide for driver versatility.
  Meets or exceeds standards set in MIL-R-83725.
asteriks Consult factory for load switching applications.
High Voltage Relay Specifications
 Contact & Relay Ratings Units G8L
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage  Max., dc or 60Hz)
kV Peak 17
 Voltage, Operating Max., Contacts & to
 Base (15 µA  Leakage Max.)
      dc or 60 Hz kV Peak 15
      2.5 MHz kV Peak 12
      16 MHz kV Peak 9
      32 MHz kV Peak 7
 Current, Continuous Carry Max
      dc or 60 Hz Amps 30
      2.5 MHz Amps 18
      16 MHz Amps 10
      32 MHz Amps 6
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 0.5
      Contacts to Ground pF 1
 Resistance, Contact Max @ 1A, 28 Vdc ohms 0.025
 Operate Time ms 15
 Reset Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 84 (3)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +125


High Voltage Relays - Coil Ratings
 Nominal, Volts dc 26.5
 Pick-up, Volts dc, Max. 16
 Reset, Volts dc 1 - 10
 Coil Resistance
 (Ohms  ±10%)
-
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
 
For more information, refer to
Relay User Instructions

 
G8 L S -

 Latching
 Designator

 High Voltage/
 Power Terminal
 Connections

 S = Solder Pot
 W = Screw

 Mounting 
 F
= Flange
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc
 
asteriks Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity.

06/13/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  