Smallest profile available
for a high power 10kV relay |
 |
 |
|
All PC pin or PC pin & flying lead
connections provide mounting and connection versatility |
 |
 |
|
Durable tungsten contacts for hot load
switching |
 |
 |
|
Vacuum dielectric for effective arc
quenching when opening under load |
|
 |
Consult factory for load switching applications |
|
 |
| Contact
& Relay Ratings |
Units |
G81C |
| Contact
Form |
 |
C |
| Contact Arrangement |
 |
SPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage Max., dc or 60Hz) |
kV
Peak |
11 |
Voltage, Operating
Max., Contacts
(15 µA Leakage Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
10 |
| 2.5
MHz |
kV Peak |
- |
| 16
MHz |
kV Peak |
- |
| 32
MHz |
kV Peak |
- |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
5,
30 |
| 2.5
MHz |
Amps |
- |
| 16
MHz |
Amps |
- |
| 32
MHz |
Amps |
- |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
NA |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
- |
| Contacts
to Ground |
pF |
- |
| Resistance, Contact
Max @ 1A, 28Vdc |
ohms |
0.05 |
| Operate
Time |
ms |
10 |
| Release Time |
ms |
10 |
| Life,
Mechanical |
cycles |
2
million |
| Weight, Nominal |
g (oz) |
70 (2.5) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
30 |
| Temperature Ambient
Operating |
°C |
-55 to +85 |
|
 |
| Nominal,
Volts dc |
12 |
26.5 |
115 |
| Pick-up,
Volts dc, Max. |
8 |
16 |
80 |
| Drop-Out, Volts dc |
.5
- 5 |
1 -
10 |
5 -
50 |
Coil
Resistance
(Ohms ±10%) |
70 |
290 |
4700 |
Ratings listed are for 25°C, sea level conditions |
For more information, refer to
Relay User Instructions
| G81 |
C |
3 |
3 |
5 |
| |
 |
 |
 |
Coil
Voltage
2 = 12 Vdc, PC Board 3
= 26.5 Vdc, PC Board 5
= 115 Vdc, PC Board |
|
High
Voltage Connections 3
= PCB Pins 4 =
Flying Leads |
|
| |
|
 |
PC pin versions carry 5 amps, see part number above. Flying
lead version carries 30 amps. |
04/03/08 |
|