Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil |
 |
| G71LA |
 |
 |
|
Sealed 70 kV isolation in about 6.3 cubic inch (100 cubic cm) package - your will be system the smallest in the industry! |
 |
 |
|
SF-6 gas filled for capacitive discharge with no x-ray emissions |
 |
 |
|
Pre-tinned, optional length, high voltage leads making installation easy fast and easy |
 |
 |
|
Great for charging & discharging capacitors with no bounce under load |
 |
 |
|
GIGAVAC exclusive replaceable coils |
 |
| G71LC |
 |
 |
|
Same great features as the G71A and G71B |
 |
 |
|
Double Throw (SPDT) for polarity reversal and multiple power source switching |
|
|
 |
| Contact
& Relay Ratings |
Units |
G71LA |
G71LC |
| Contact
Form |
 |
A |
C |
| Contact Arrangement |
 |
SPST |
SPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage Max,
dc or 60Hz) |
kV
Peak |
75 |
75 |
| Voltage, Operating
Max., Contacts & to Base (15 µA Leakage
Max.) |
 |
 |
 |
| dc |
kV Peak |
70 |
70 |
| 60
Hz RMS |
kV Peak |
30 |
30 |
| 2.5
MHz |
kV Peak |
- |
- |
| 16
MHz |
kV Peak |
- |
- |
| 32
MHz |
kV Peak |
- |
- |
| Current,
Continuous Carry Max |
 |
 |
 |
| dc
or 60 Hz |
Amps |
10 |
10 |
| 2.5
MHz |
Amps |
- |
- |
| 16
MHz |
Amps |
- |
- |
| 32
MHz |
Amps |
- |
- |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
500 |
| Capacitance |
 |
 |
 |
| Across
Open Contacts |
pF |
- |
- |
| Contacts
to Ground |
pF |
- |
- |
| Resistance, Contact
Max @ 1A, 28 Vdc |
ohms |
2.0 |
2.0 |
| Operate
Time |
ms |
20 |
20 |
| Reset Time |
ms |
15 |
15 |
| Life,
Mechanical |
cycles |
.5
million |
.5
million |
| Weight, Nominal |
g (oz) |
336 (12) |
336 (12) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
10 |
| Shock, Operating,
1/2 Sine 11ms (Peak) |
G's |
20 |
20 |
| Temperature Ambient
Operating |
°C |
-50 to +85 |
-50 to +85 |
|
 |
| Nominal,
Volts dc |
26.5 |
| Pick-up,
Volts dc, Max. |
22 |
| Reset, Volts dc |
1 - 10 |
| Coil
Resistance (Ohms ±10%) |
- |
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals. |
For more information, refer to
Relay User Instructions
| G71 |
L |
A |
8 |
4 |
1 |
| |
 |
 |
 |
 |
Contact Form
A = SPST
C = SPDT |
|
Coil Voltage  
8 = 26.5 Vdc, Turret Terminal |
|
High Voltage Connections
4 = Flying Leads, 12"
7 = Flying Leads, 72"
8 = Flying Leads, 36" |
|
|
|
 |
Contact resistance for gas-filled measuredat
28 Vdc, 1 Amp |
  |
Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity. |
04/03/08 |
|