G64L 50kV Latching Make Only Load Switching Relay 50 kv relay  
 Make Only Load Switching
 

G64L LATCHING RELAYS
G64LC
High Voltage Relay Features
  Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil
  Compact design saves precious space while isolating 50kV
  Flying leads provide versatile high voltage connections
  Excellent for capacitive discharge and safety dump switch applications
  Effectively bounce free operation
High Voltage Relay Specifications
 Contact & Relay Ratings Units G64LC
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage Max., dc or 60Hz)
kV Peak 55
 Voltage, Operating Max., Contacts & to
 Base (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 50
      2.5 MHz kV Peak -
      16 MHz kV Peak -
      32 MHz kV Peak -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 10
      2.5 MHz Amps -
      16 MHz Amps -
      32 MHz Amps -
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF -
      Contacts to Ground pF -
 Resistance, Contact Max @ 1A, 28 Vdc ohms 1.0
 Operate Time ms 15
 Reset Time ms 15
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 336 (12)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 10
 Temperature Ambient Operating °C -55 to +85

High Voltage Relays - Coil Ratings
 Nominal, Volts dc 26.5
 Pick-up, Volts dc, Max. 18
 Reset, Volts dc 1 - 10
 Coil Resistance (Ohms  ±10%) -
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
 
 
For more information, refer to
Relay User Instructions

 
G64 L   C 8    4    1
 Latching
 Designator
 Contact Form
 C = SPDT
 Coil Voltage 
 8 = 26.5 Vdc, Turret Terminal
 High Voltage Connections
 4 = Flying Leads, 12"
 7 = Flying Leads, 72"
 8 = Flying Leads, 36"
 Mounting
 1 = Threaded
 
asteriks Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity.

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  