G61A - G61B - G61C 35kV Make Only Load Switching Relay Datasheet 35 kv relay  
 Make Only Load Switching
 RoHS Compliant
 

G61A G61B Make Only Load Switching
 

G61C Make Only Load Switching
G61 A - G61 B - G61 C
 
High Voltage Relay Features
 G61A & G61B & G61C
 Make Only Load Switchings
  Compact design saves precious space while isolating 35kV
  Flying leads provide versatile high voltage connections
  Excellent for capacitive discharge and safety dump switch applications
  Effectively bounce free operation
High Voltage Relay Specifications
 Contact & Relay Ratings Units G61A G61B G61C
 Contact Form A B C
 Contact Arrangement SPST-NO SPST-NC SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage Max, dc or 60Hz)
kV Peak 40 40 40
 Voltage, Operating Max., Contacts &  to  Base (15 µA Leakage Max.)
      dc kV Peak 35 35 35
      60 Hz RMS kV Peak 30 30 30
      2.5 MHz kV Peak - - -
      16 MHz kV Peak - - -
      32 MHz kV Peak - - -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 10 10 10
      2.5 MHz Amps - - -
      16 MHz Amps - - -
      32 MHz Amps - - -
 Coil Hi-Pot (V RMS, 60 Hz) V 500 500 500
 Capacitance
      Across Open Contacts pF - - -
      Contacts to Ground pF - - -
 Resistance, Contact Max @ 1A, 28  Vdc ohms 1.0 1.0 1.0
 Operate Time ms 15 15 15
 Release Time ms 15 15 15
 Life, Mechanical cycles 1 million 1 million 1 million
 Weight, Nominal g (oz) 336 (12) 336 (12) 336 (12)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10 10 10
 Shock, Operating, 1/2 Sine  11ms (Peak) G's 20 20 20
 Temperature Ambient Operating °C -55 to +85 -55 to +85 -55 to +85

 
High Voltage Relays - Coil Ratings
 Nominal, Volts dc 12 26.5 115
 Pick-up, Volts dc, Max. 9 18 90
 Drop-Out, Volts dc .5 - 5 1 - 10 5 - 50
 Coil Resistance
 (Ohms  ±10%)
30 125 2000
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G61 A 7 4 1
 Contact Form
 A = SPST-NO
 B = SPST-NC
 C = SPDT
 Coil Voltage 
 7
= 12 Vdc, Turret Terminal
 8 = 26.5 Vdc, Turret Terminal
 9 = 115 Vdc, Turret Terminal
 High Voltage Connections
 4 = Flying Leads, 12"
 7 = Flying Leads, 72"
 8 = Flying Leads, 36"
 Mounting
 1 = Threaded
09/06/11
GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000
fx +(805) 684-8402 -   - www.gigavac.com - ©Copyright 2003-2012 GIGAVAC, LLC.