G60L 35kV Latching Make Only Load Switching Relay Datasheet 35 kv relay  
 Make Only Load Switching (Requires relay to be potted to be able to meet high voltage specifications)
 RoHS Compliant, date code 0601 and later
 

G60L Latching Make Only Load Switching Relay  


G60 C Latching High Voltage Relays

High Voltage Relay Features
  Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil
  Unglazed ceramic relay offers true customer design flexibility
  Excellent for capacitive discharge and safety dump switch applications
  Effectively bounce free operation
High Voltage Relay Specifications
 Contact & Relay Ratings Units G60LC
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage Max., dc or 60Hz)
kV Peak 40asteriks
 Voltage, Operating Max., Contacts & to
 Base (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 35asteriks
      2.5 MHz kV Peak -
      16 MHz kV Peak -
      32 MHz kV Peak -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 12
      2.5 MHz Amps -
      16 MHz Amps -
      32 MHz Amps -
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF -
      Contacts to Ground pF -
 Resistance, Contact Max @ 1A, 28 Vdc ohms 1.0
 Operate Time ms 15
 Reset Time ms 15
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 84 (3)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +125


High Voltage Relays - Coil Ratings
 Nominal, Volts dc 26.5
 Pick-up, Volts dc, Max. 18
 Reset, Volts dc 1 - 10
 Coil Resistance
 (Ohms  ±10%)
-
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
 
 
For more information, refer to
Relay User Instructions

 
G60 L C S P -

 Latching
 Designator

 Contact Form
 C
= SPDT

 High Voltage/
 Power Terminal
 Connections

 S = Solder Pot

 Mounting 
 P = Through Panel
 Coil Voltage
 Blank = 26.5 Vdc
asteriks Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity.

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  