G5P 5kV Make & Break Load Switching Relay 5 kv relay  
 Design Specifications
 RoHS Compliant, date code 0601 and later
High Voltage Relay Features
  Latching design for low power consumption
  Fast operate time
  Five times the life of our non-latching relays
  Highest RF & DC carry current
  -55°C to 100ºC operating temperatures (more extremes available)
  Slim design for maximum packing density
  Can be mounted in any position
  Meets or exceeds MIL-R-83725 Standards
See Mounting & Coil Terminations for additional Options 
High Voltage Relay Specifications
 Contact & Relay Ratings Units G5P
 Contact Form P
 Contact Arrangement SPST-Latching
 Voltage, Test Max., Contacts & to
 Base  (15 µA Leakage Max., dc or 60Hz)
kV Peak 6
 Voltage, Operating Max., Contacts & to
 Base  (20 µA Leakage Max., dc & 60Hz)
      dc or 60 Hz kV Peak 5
      2.5 MHz kV Peak 4.5
      16 MHz kV Peak 3.5
      32 MHz kV Peak 2.8
 Current, Continuous Carry Max
      dc or 60 Hz Amps 35
      2.5 MHz Amps 21
      16 MHz Amps 14
      32 MHz Amps 8
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 1.2
      Contacts to Ground pF 1.2
 Resistance, Contact Max @ 1A, 28Vdc ohms 0.02
 Latch & Reset time (including bounce)
  with 13Vdc to 32Vdc coil voltage @ 25C
ms 2
 Latch & Reset time (including bounce)
  with 13Vdc to 32Vdc coil voltage @ 100C
ms 2.5
 Life, Mechanical cycles 5 million
 Weight, Nominal g (oz) 28 (1)
 Vibration, Operating, Sine (55-2000 Hz  Peak) G's 30
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +100
High Voltage Relays - Coil Ratings
 Nominal, Volts dc 26.5
 Nominal, Volts dc* 26.5
 Max, Volts dc* 32
 Latch & Reset Volts,
 dc Max @ 25C
15.5
 Latch & Reset Volts,
 dc Max @100C
20
 Latch & Reset Voltage,
 dc Min @ -55C
1.5
 Coil Resistance (Ohms +-10%) 80
* Not for continious duty -10% maxium duty
cycle. 2.5 ms minimum and 1 sec
maximum energize time. 
 
For more information, refer to
Relay User Instructions

 
G5 P 3 3 2

 Contact  Form
 P = SPST - Latching

 Coil Voltage
 3 = 26.5 Vdc, Bus Wire

 High Voltage Connections 
 3
= Solder Connection
 4 = Double Sided Solder Connection
 Mounting
 2 = Flanged
 4 = Standard