High carry current, 150
amps continuous, in a small package |
 |
 |
|
Low, stable contact resistance minimizes
loss in RF circuits |
 |
 |
|
Threaded high voltage connections help
make installation easy |
 |
 |
|
Meets or exceeds standards set in MIL-R-83725 |
|
|
 |
| Contact
& Relay Ratings |
Units |
G52 |
| Contact
Form |
 |
C |
| Contact Arrangement |
 |
SPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage Max., dc or
60Hz) |
kV
Peak |
30 |
Voltage, Operating
Max., Contacts & to
Base (15 µA Leakage Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
25 |
| 2.5
MHz |
kV Peak |
15 |
| 13.56
MHz |
kV Peak |
10 |
| 32
MHz |
kV Peak |
7 |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
150 |
| 2.5
MHz |
Amps |
120 |
| 13.56 MHz |
Amps |
75 |
| 32
MHz |
Amps |
30 |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
5 |
| Contacts
to Ground |
pF |
5 |
| Resistance, Contact
Max @ 1A, 28 Vdc |
ohms |
0.003 |
| Operate
Time |
ms |
100 |
| Release Time |
ms |
15 |
| Life,
Mechanical |
cycles |
1 million |
| Weight, Nominal |
g (oz) |
1000 (35) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
30 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
| Maximum Terminal Temperature
|
°C |
200 |
|
 |
| Nominal,
Volts dc |
26.5 |
| Pick-up,
Volts dc, Max. |
16 |
| Drop-Out, Volts dc |
1-10 |
| Coil
Resistance (Ohms ±10%) |
60 |
Ratings listed are for 25°C, sea level conditions |
For more information, refer to
Relay User Instructions
|
 |
Order the relay with the
coil voltage in the part number as shown above. The coil voltage
will appear on the coil plate near the coil terminals rather
than in the P/N on the relay. |
02/22/10 |
|