| Contact
& Relay Ratings |
Units |
G50 |
| Contact
Form |
 |
C |
| Contact Arrangement |
 |
SPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage Max., dc or
60Hz) |
kV
Peak |
30 |
Voltage, Operating
Max., Contacts & to
Base (15 µA Leakage Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
25 |
| 2.5
MHz |
kV Peak |
- |
| 16
MHz |
kV Peak |
- |
| 32
MHz |
kV Peak |
- |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
110 |
| 2.5
MHz |
Amps |
- |
| 16
MHz |
Amps |
- |
| 32
MHz |
Amps |
- |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
5 |
| Contacts
to Ground |
pF |
5 |
| Resistance, Contact
Max @ 1A, 28 Vdc |
ohms |
0.005 |
| Operate
Time |
ms |
100 |
| Release Time |
ms |
15 |
| Life,
Mechanical |
cycles |
1 million |
| Weight, Nominal |
g (oz) |
1000 (35) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
30 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
| Maximum Terminal Temperature |
°C |
200 |
|
 |
| Nominal,
Volts dc |
26.5 |
| Pick-up,
Volts dc, Max. |
16 |
| Drop-Out, Volts dc |
1-10 |
| Coil
Resistance (Ohms ±10%) |
60 |
Ratings listed are for 25°C, sea level conditions |