G45C 5kV Make & Break Load Switching Relay 5 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0601 and later

 

G45C HIGH VOLTAGE RELAY

 
G45 C
High Voltage Relay Features
  Smallest size double throw, 5 kV, RF rated relay with it's current ratings
  Very low profile, even when wires connected
  Vacuum dielectric for low current power switching
  Low coil power
  Meets or exceeds MIL-R-83725
 
See Mounting & Coil Terminations
for additional Options
High Voltage Relay Specifications
 Contact & Relay Ratings Units G45C
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base  (15 µA Leakage Max., dc or 60Hz)
kV Peak 6
 Voltage, Operating Max., Contacts & to
 Base  (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 5
      2.5 MHz kV Peak 4.5
      16 MHz kV Peak 3.5
      32 MHz kV Peak 2.8
 Current, Continuous Carry Max
      dc or 60 Hz Amps 20
      2.5 MHz Amps 16
      16 MHz Amps 10
      32 MHz Amps 8
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 1.6
      Contacts to Ground pF 2
 Resistance, Contact Max @ 1A, 28Vdc ohms 0.05
 Operate Time ms 10
 Release Time ms 10
 Life, Mechanical cycles 2 million
 Weight, Nominal g (oz) 21 (0.75)
 Vibration, Operating, Sine (10-2000 Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 30
 Temperature Ambient Operating °C -55 to +125

High Voltage Relays - Coil Ratings
 Nominal, Volts dc 12 26.5
 Pick-up, Volts dc, Max. 8 16
 Drop-Out, Volts dc .5 - 5 1 - 10
 Coil Resistance
 (Ohms  ±10%)
230 920
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G45 C 3 3 4
 Contact Form
 C = SPDT
 Coil Voltage 
 2
= 12 Vdc, Bus Wire
 3 = 26.5 Vdc, Bus Wire
 High Voltage Connections
 3 = Solder Connection
 Mounting
 2 = Flanged
 4 = Standard
04/03/08