G41A - G41B - G41C 5kV Make & Break Load Switching Relay 5 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0601 and later
 
G41A G41 B RELAYS

G41 A - G41 B

 
G41C HIGH VOLTAGE RELAY
G41 C
High Voltage Relay Features
  Slim design is extremely space efficient in multi-relay applications
  RF efficient design offers high power handling in a small package
  Durable tungsten contacts for hot load switchingasteriks
  Vacuum dielectric for effective arc quenching when opening under loadasteriks
  Can be mounted and used in any position
  Meets or exceeds standards set in MIL-R-83725
asteriks Consult factory for load switching applications.
 
See Mounting & Coil Terminations
for additional Options
High Voltage Relay Specifications
 Contact & Relay Ratings Units G41A G41B G41C
 Contact Form A B C
 Contact Arrangement SPST-NO SPST-NC SPDT
 Voltage, Test Max., Contacts & to
 Base
(15 µA Leakage Max., dc or 60Hz)
kV Peak 6 6 6
 Voltage, Operating Max., Contacts
 & to Base (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 5 5 5
      2.5 MHz kV Peak 4.5 4.5 4.5
      16 MHz kV Peak 3.5 3.5 3.5
      32 MHz kV Peak 2.8 2.8 2.8
 Current, Continuous Carry Max
      dc or 60 Hz Amps 30 30 30
      2.5 MHz Amps 24 24 24
      16 MHz Amps 16 16 16
      32 MHz Amps 12 12 12
 Coil Hi-Pot (V RMS, 60 Hz) V 500 500 500
 Capacitance
      Across Open Contacts pF 1.2 1.2 1.2
      Contacts to Ground pF 1.2 1.2 1.2
 Resistance, Contact Max @ 1A,  28Vdc ohms 0.02 0.02 0.02
 Operate Time ms 10 10 10
 Release Time ms 10 10 10
 Life, Mechanical cycles 2 million 2 million 2 million
 Weight, Nominal g (oz) 28 (1) 28 (1) 28 (1)
 Vibration, Operating,
 Sine (55-2000  Hz  Peak)
G's 10 10 10
 Shock, Operating, 1/2 Sine  11ms (Peak) G's 50 50 50
 Temperature Ambient Operating °C -55 to +125 -55 to +125 -55 to +125

 
High Voltage Relays - Coil Ratings
 Nominal, Volts dc 12 26.5 115
 Pick-up, Volts dc, Max. 8 16 80
 Drop-Out, Volts dc .5 - 5 1 - 10 5 - 50
 Coil Resistance
 (Ohms  ±10%)
70 290 4700
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G41 A 3 3 4
 Contact Form
 A = SPST-NO
 B = SPST-NC
 C = SPDT
 Coil Voltage 
 2
= 12 Vdc, Bus Wire
 3 = 26.5 Vdc, Bus Wire
 5 = 115 Vdc, Bus Wire
 7 = 12 Vdc, Turret Terminal
 8 = 26.5 Vdc, Turret Terminal
 9 = 115 Vdc, Turret Terminal
 High Voltage Connections
 3 = Solder Connection
 Mounting
 2 = Flanged
 4 = Standard
04/03/08
GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  