Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil |
 |
 |
|
High carry current, 50Adc
continuous, in a small package |
 |
 |
|
Low, stable contact resistance minimizes
loss in RF circuits |
 |
 |
|
Two mounting styles available, flange
or through panel with jam nut |
 |
 |
|
Solder or threaded high voltage connections
help make installation easy |
 |
 |
|
User interchangeable coils provide for
driver versatility |
 |
 |
|
Meets or exceeds standards set in MIL-R-83725 |
|
|
 |
| Contact
& Relay Ratings |
Units |
G2L |
| Contact
Form |
 |
C |
| Contact Arrangement |
 |
SPDT |
Voltage,
Test Max., Contacts & to Base (15 µA Leakage
Max., dc or 60Hz) |
kV
Peak |
17 |
Voltage, Operating
Max., Contacts & to Base (15 µA Leakage
Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
15 |
| 2.5
MHz |
kV Peak |
12 |
| 16
MHz |
kV Peak |
9 |
| 32
MHz |
kV Peak |
7 |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
50 |
| 2.5
MHz |
Amps |
30 |
| 16
MHz |
Amps |
17 |
| 32
MHz |
Amps |
10 |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
0.5 |
| Contacts
to Ground |
pF |
1 |
| Resistance, Contact
Max @ 1A, 28 Vdc |
ohms |
0.012 |
| Operate
Time |
ms |
15 |
| Reset Time |
ms |
9 |
| Life,
Mechanical |
cycles |
1 million |
| Weight, Nominal |
g (oz) |
84 (3) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
50 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
|
 |
| Nominal,
Volts dc |
26.5 |
| Pick-up,
Volts dc, Max. |
16 |
| Reset, Volts dc |
1 -
10 |
Coil
Resistance
(Ohms ±10%) |
- |
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
|
For more information, refer to
Relay User Instructions
|
 |
Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity. |
04/03/08 |
|
 |
 |
 |
 |
 |
 |
|
 |
GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000 |
|