Double Pole Double Throw, DPDT, contact arrangement for maximum circuit design flexibility |
 |
 |
|
Copper contacts provide low contact resistance for increased current carry |
 |
 |
|
Low, stable contact resistance minimizes loss in RF circuits |
 |
 |
|
Threaded high voltage connections for easy installation |
 |
 |
|
User interchangeable coils provide driver versatility |
|
|
 |
| Contact
& Relay Ratings |
Units |
G23 |
| Contact
Form |
 |
2C |
| Contact Arrangement |
 |
DPDT |
Voltage,
Test Max., Contacts & to
Base (15 µA Leakage Max., dc or 60Hz) |
kV
Peak |
23 |
Voltage, Operating
Max., Contacts & to
Base (15 µA Leakage Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
20 |
| 2.5
MHz |
kV Peak |
12 |
| 16
MHz |
kV Peak |
8 |
| 32
MHz |
kV Peak |
5 |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
75 |
| 2.5
MHz |
Amps |
35 |
| 16
MHz |
Amps |
22 |
| 32
MHz |
Amps |
15 |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
3 |
| Contacts
to Ground |
pF |
3.5 |
| Resistance, Contact
Max @ 1A, 28Vdc |
ohms |
0.010 |
| Operate
Time |
ms |
30 |
| Release Time |
ms |
10 |
| Life,
Mechanical |
cycles |
1
million |
| Weight, Nominal |
g (oz) |
380 (14) |
| Vibration,
Operating, Sine (55-300 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
50 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
|
 |
| Nominal,
Volts dc |
26.5 |
| Pick-up,
Volts dc, Max. |
16 |
| Drop-Out, Volts dc |
1-10 |
Coil
Resistance
(Ohms ±10%) |
240 |
|
For more information, refer to
Relay User Instructions
|
 |
Order the relay with the coil voltage
in the part number as shown above. The coil voltage will appear
on the coil plate near the coil terminals rather than in the
P/N on the relay. |
02/16/10
|
|