G2SPD G8SPD G15SPD High Voltage Relays 12 kv relay  
RoHS Compliant
G2SPD G8SPD G15SPD RELAYS

G2SPD G8SPD G15SPD drawing

High Voltage Relay Features
  Space efficient design.
  Three versions offer different capabilities.
  Easy to mount threaded base.
  User interchangeable coils.
  Meets or exceeds standard in MIL-R-83725.
 G2SPD G8SPD G15SPD drawing
High Voltage Relay Specifications
 Contact & Relay Ratings Units G2SPD G8SPD G15SPD
 Contact Form C C C
 Contact Arrangement DPDT DPDT DPDT
      Contact Material
      (moveable/stationary)
molybdenum
/copper
molybdenum
/tungsten
molybdenum
/tungsten
      Dielectric vacuum vacuum gas mixture
 Voltage, Test Max.,
 Contacts & to Base
 (15 µA Leakage  Max.,
 dc or 60Hz)
kV Peak 17 17 17
 Voltage, Operating Max., Contacts & to Base (15 µA  Leakage Max.)
      dc or 60 Hz kV Peak 15 15 15
      2.5 MHz kV Peak 12 12 -
      16 MHz kV Peak 9 9 -
      32 MHz kV Peak 7 7 -
 Current, Load Switching
 (make & break 10A
  @ 150Vdc)
cycles 500 10,000 make only**
 Current, Continuous Carry Max
      dc or 60 Hz Amps 50 30 12
      2.5 MHz Amps 30 18 -
      16 MHz Amps 17.5 10 -
      32 MHz Amps 12 6 -
 Coil Hi-Pot (V RMS, 60 Hz) V 500 500 500
 Capacitance
      Across Open Contacts pF 1 1 -
      Contacts to Ground pF 2.5 2.5 -
 Resistance,
  Contact Max @ 1A, 28 Vdc
ohms 0.012 0.025 0.025
 Operate Time ms 20 20 20
 Release Time ms 8 8 8
 Life, Mechanical cycles 1 million 1 million 1 million
 Weight, Nominal g (oz) 160 (6) 160 (6) 160 (6)
 Vibration, Operating,
  Sine (55-500  Hz  Peak)
G's 10 10 10
 Shock, Operating,
  1/2 Sine11ms (Peak)
G's 1.5 1.5 1.5
 Temperature Ambient
  Operating
°C -55 to +125 -55 to +125 -55 to +125
** Consult factory.
High Voltage Relay Coil Ratings
 Nominal, Volts dc 12 26.5
 Pick-up, Volts dc, Max. 8 16
 Drop-Out, Volts dc .5 - 5 1 - 10
 Coil Resistance
 (Ohms  ±10%)
60 285
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G 2 S P  - 12Vdc
 Model
 2
 8
 15

 High Voltage/
Power Terminal
Connections

 S = Solder Pot

 Mounting 
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc
 12Vdc = 12 Vdc
 
asteriks Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.

 

08/25/11

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000
fx +(805) 684-8402 -   - www.gigavac.com - ©Copyright 2003-2012 GIGAVAC, LLC.