Durable tungsten contacts
for hot load switching. |
 |
 |
|
Internal dielectric shield provides superior hot switch ratings. |
 |
 |
|
Vacuum dielectric for effective arc
quenching when opening under load. |
 |
 |
|
Two mounting styles available, flange
or through panel with jam nut. |
 |
 |
|
Solder or threaded high voltage connections
help make installation easy. |
 |
 |
|
User interchangeable coils provide for
driver versatility. |
 |
 |
|
Meets or exceeds standards set in MIL-R-83725. |
|
|
 |
| Contact
& Relay Ratings |
Units |
G18 |
| Contact
Form |
 |
C |
| Contact Arrangement |
 |
SPDT |
Voltage,
Test Max., Contacts & to Base (15 µA Leakage
Max., dc or 60Hz) |
kV
Peak |
17 |
Voltage, Operating
Max., Contacts & to Base (15 µA Leakage
Max.) |
 |
 |
| dc
or 60 Hz |
kV Peak |
15 |
| 2.5
MHz |
kV Peak |
- |
| 16
MHz |
kV Peak |
- |
| 32
MHz |
kV Peak |
- |
| Current,
Continuous Carry Max |
 |
 |
| dc
or 60 Hz |
Amps |
30 |
| 2.5
MHz |
Amps |
- |
| 16
MHz |
Amps |
- |
| 32
MHz |
Amps |
- |
| Coil Hi-Pot (V RMS,
60 Hz) |
V |
500 |
| Capacitance |
 |
 |
| Across
Open Contacts |
pF |
0.5 |
| Contacts
to Ground |
pF |
1 |
| Resistance, Contact
Max @ 1A, 28 Vdc |
ohms |
0.025 |
| Operate
Time |
ms |
15 |
| Release Time |
ms |
9 |
| Life,
Mechanical |
cycles |
1 million |
| Weight, Nominal |
g (oz) |
84 (3) |
| Vibration,
Operating, Sine (55-500 Hz Peak) |
G's |
10 |
| Shock, Operating,
1/2 Sine11ms (Peak) |
G's |
50 |
| Temperature Ambient
Operating |
°C |
-55 to +125 |
|
 |
| Nominal,
Volts dc |
12 |
26.5 |
115 |
| Pick-up,
Volts dc, Max. |
8 |
16 |
80 |
| Drop-Out, Volts dc |
.5
- 5 |
1 -
10 |
5 -
50 |
Coil
Resistance
(Ohms ±10%) |
48 |
180 |
2900 |
Ratings listed are for 25°C, sea level conditions |
For more information, refer to
Relay User Instructions
|
 |
Order the relay with the coil voltage
in the part number as shown above. The coil voltage will appear
on the coil plate near the coil terminals rather than in the
P/N on the relay. |
|

SWITCHING UNDER LOAD
500V and below: Relay may be on either side of the load and the case may be floating or grounded.
See High Voltage Relay Grounding Requirements for details.
Above 500V: The relay must be on the ground side of the load and the case MUST be grounded.
See High Voltage Relay Grounding Requirements for details.
 |
| DC Voltage |
Current (Amps) |
Load Life (Cycles) |
| 330 |
17 |
10,000 |
| 330 |
5 |
100,000 |
| 5kV |
2 |
100,000 |
| 10kV |
1 |
50,000 |
Contact GIGAVAC for Normally open Contact ratings.
04/03/08 |
|