G15L 15kV Latching Make Only Load Switching Relay 15 kv High Voltage Relays  
 Make Only Load Switching
 RoHS Compliant, date code 0701 and later
  
G15L Latching RELAYS

G15 Latching HIGH VOLTAGE RELAY
 

G 15L, G15 Latching relays
High Voltage Relay Features
  Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil
  Excellent for capacitive discharge and safety dump switch applications
  Two mounting styles available, flange or through panel with jam nut
  Solder or threaded high voltage connections help make installation easy
  User interchangeable coils provide for driver versatility
  Effectively bounce free operation
High Voltage Relays Specs
 Contact & Relay Ratings Units G15L
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage  Max., dc or 60Hz)
kV Peak 17
 Voltage, Operating Max., Contacts & to
 Base (15 µA  Leakage Max.)
      dc or 60 Hz kV Peak 15
      2.5 MHz kV Peak -
      16 MHz kV Peak -
      32 MHz kV Peak -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 12
      2.5 MHz Amps -
      16 MHz Amps -
      32 MHz Amps -
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF -
      Contacts to Ground pF -
 Resistance, Contact Max @ 1A, 28 Vdc ohms 1.0
 Operate Time ms 15
 Reset Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 84 (3)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +125

 

High Voltage Relay Coil Ratings
 Nominal, Volts dc 26.5
 Pick-up, Volts dc, Max. 16
 Reset, Volts dc 1 - 10
 Coil Resistance
 (Ohms  ±10%)
-
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
 
 
For more information, refer to
Relay User Instructions

 
G15 L S -

 Latching
 Designator

 High Voltage/
 Power Terminal
 Connections

 S = Solder Pot
 W = Screw

 Mounting 
 F
= Flange
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc


asteriks Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity.

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  