G15 15kV Make Only Load Switching Relay 15 kv High Voltage Relays  
 Make Only Load Switching
 RoHS Compliant, date code 0701 and later
  
G15 RELAYS

G15 HIGH VOLTAGE RELAY
 


G 15, G15

 

High Voltage Relay Features
  Excellent for capacitive discharge and safety dump switch applications
  Two mounting styles available, flange or through panel with jam nut
  Solder or threaded high voltage connections help make installation easy
  User interchangeable coils provide for driver versatility
  Effectively bounce free operation
High Voltage Relays Specs
 Contact & Relay Ratings Units G15
 Contact Form C
 Contact Arrangement SPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage  Max., dc or 60Hz)
kV Peak 17
 Voltage, Operating Max., Contacts & to
 Base (15 µA  Leakage Max.)
      dc or 60 Hz kV Peak 15
      2.5 MHz kV Peak -
      16 MHz kV Peak -
      32 MHz kV Peak -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 12
      2.5 MHz Amps -
      16 MHz Amps -
      32 MHz Amps -
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF -
      Contacts to Ground pF -
 Resistance, Contact Max @ 1A, 28 Vdc ohms 1.0
 Operate Time ms 15
 Release Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 84 (3)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +125

 

High Voltage Relay Coil Ratings
 Nominal, Volts dc 12 26.5 115
 Pick-up, Volts dc, Max. 8 16 80
 Drop-Out, Volts dc .5 - 5 1 - 10 5 - 50
 Coil Resistance
 (Ohms  ±10%)
48 180 2900
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G15 S F  - 12Vdc

 High Voltage/
Power Terminal
Connections

 S = Solder Pot
 W = Screw

 Mounting 
 F
= Flange
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc
 12Vdc = 12 Vdc
 115Vdc = 115 Vdc
asteriks Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.

 

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  