G13 15kV Make Only Load Switching Relay 15 kv relay  
 Make Only Load Switching
 
G13 hv relay


 




 
 

High Voltage Relay Features
  2 pole, Double Throw for switching between and/or reversing power sources or loads.
  Completely sealed for years of failure free operation.
  SF6 gas filled for high energy in-rush switching. asteriks
  Insulated flying leads make connection easy. Custom lengths available.
  Not position sensitive allowing mounting flexibility.
  Threaded base and top tabs provide mounting flexibility.
asteriks Consult factory for load switching applications.
 
High Voltage Relay Specifications
 Contact & Relay Ratings Units G13
 Contact Form 2C
 Contact Arrangement DPDT
 Voltage, Test Max., Contacts & to
 Base (15 µA Leakage  Max., dc or 60Hz)
kV Peak 17
 Voltage, Operating Max., Contacts & to
 Base (15 µA  Leakage Max.)
      dc or 60 Hz kV Peak 15
      2.5 MHz kV Peak -
      16 MHz kV Peak -
      32 MHz kV Peak -
 Current, Continuous Carry Max
      dc or 60 Hz Amps 10
      2.5 MHz Amps -
      16 MHz Amps -
      32 MHz Amps -
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 0.5
      Contacts to Ground pF 1
 Resistance, Contact Max @ 1A, 28 Vdc ohms 1.0
 Operate Time ms 15
 Release Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 140 (5)
 Vibration, Operating, Sine (55-500  Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 50
 Temperature Ambient Operating °C -55 to +85


High Voltage Relays - Coil Ratings
 Nominal, Volts dc 12 26.5 115
 Pick-up, Volts dc, Max. 8 16 80
 Drop-Out, Volts dc .5 - 5 1 - 10 5 - 50
 Coil Resistance
 (Ohms  ±10%)
48 180 2900
Ratings listed are for 25°C, sea level conditions
 
For more information, refer to
Relay User Instructions

 
G13      - 12Vdc
 
 Coil Voltageasteriks
 Blank = 26.5 Vdc
 12Vdc = 12 Vdc
 115Vdc = 115 Vdc


asteriks Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.

 

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  
fx +(805) 684-8402 -   - www.gigavac.com - ©Copyright 2003-2008 GIGAVAC, LLC.