G12L 8kV Latching High Voltage Relay 8 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0701 and later
 

G12L Latching High Voltage Relay
 
G 12 Latching 
High Voltage Relay Features
  Latching coils for low power consumption and to ensure relay will remain in last position, even when no voltage is applied to the coil
  Smallest ceramic DPDT high voltage relay, more robust than glass
  Vacuum dielectric and Tungsten contacts for power switching
  8 kV rating
  Meets or exceeds MIL-R-83725
  User interchangeable coils provide for driver versatility
High Voltage Relay Specifications
 Contact & Relay Ratings Units G12L
 Contact Form 2C
 Contact Arrangement DPDT
 Voltage, Test Max., Contacts & to
 Base  (15 µA Leakage Max., dc or 60Hz)
kV Peak 10
 Voltage, Operating Max., Contacts & to
 Base  (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 8
      2.5 MHz kV Peak 5
      16 MHz kV Peak 3
      32 MHz kV Peak 2
 Current, Continuous Carry Max
      dc or 60 Hz Amps 10
      2.5 MHz Amps 7
      16 MHz Amps 3
      32 MHz Amps 2
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 0.8
      Contacts to Ground pF 1.5
 Resistance, Contact Max @ 1A, 28Vdc ohms 0.020
 Operate Time ms 15
 Reset Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 71 (2.5)
 Vibration, Operating, Sine (10-2000 Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 30
 Temperature Ambient Operating °C -55 to +125

 

High Voltage Relays - Coil Ratings
 Nominal, Volts dc 26.5
 Pick-up, Volts dc, Max. 16
 Reset, Volts dc 1-10
 Coil Resistance
 (Ohms  ±10%)
-
Ratings listed are for 25°C, sea level conditions.
Coils are polarity sensitive.
Observe polarity marked on coil terminals.
 
For more information, refer to
Relay User Instructions

 
G12 L S P  -

Latching
Designator

High Voltage/
Power Terminal
Connections

 S = Solder Tab

 Mounting 
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc


asteriks Order the relay with the part number as shown. The latching "L" designator and the coil voltage will not appear in the P/N on the relay but will be indicated on the label that is on the base of the relay. Observe coil polarity.

 

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  