G12 8kV High Voltage Relay 8 kv relay  
 Make & Break Load Switching
 RoHS Compliant, date code 0701 and later
 

G12 High Voltage Relay
 
G 12 
High Voltage Relay Features
  Smallest ceramic DPDT high voltage relay, more robust than glass
  Vacuum dielectric and Tungsten contacts for power switching
  8 kV rating
  Meets or exceeds MIL-R-83725
  User interchangeable coils provide for driver versatility
High Voltage Relay Specifications
 Contact & Relay Ratings Units G12
 Contact Form 2C
 Contact Arrangement DPDT
 Voltage, Test Max., Contacts & to
 Base  (15 µA Leakage Max., dc or 60Hz)
kV Peak 10
 Voltage, Operating Max., Contacts & to
 Base  (15 µA Leakage Max.)
      dc or 60 Hz kV Peak 8
      2.5 MHz kV Peak 5
      16 MHz kV Peak 3
      32 MHz kV Peak 2
 Current, Continuous Carry Max
      dc or 60 Hz Amps 10
      2.5 MHz Amps 7
      16 MHz Amps 3
      32 MHz Amps 2
 Coil Hi-Pot (V RMS, 60 Hz) V 500
 Capacitance
      Across Open Contacts pF 0.8
      Contacts to Ground pF 1.5
 Resistance, Contact Max @ 1A, 28Vdc ohms 0.020
 Operate Time ms 15
 Release Time ms 9
 Life, Mechanical cycles 1 million
 Weight, Nominal g (oz) 71 (2.5)
 Vibration, Operating, Sine (10-2000 Hz  Peak) G's 10
 Shock, Operating, 1/2 Sine11ms (Peak) G's 30
 Temperature Ambient Operating °C -55 to +125

 

High Voltage Relays - Coil Ratings
 Nominal, Volts dc 12 26.5 115
 Pick-up, Volts dc, Max. 8 16 80
 Drop-Out, Volts dc 0.5-5 1-10 5-50
 Coil Resistance
 (Ohms  ±10%)
60 250 3500
For more information, refer to
Relay User Instructions

 
G12 S P  - 12Vdc

 High Voltage/
Power Terminal
Connections

 S = Solder Tab

 Mounting 
 P = Through Panel
 Coil Voltageasteriks
 Blank = 26.5 Vdc
 12Vdc = 12 Vdc
 115Vdc = 115 Vdc
   

 

04/03/08

GIGAVAC HV Relays GIGAVAC® - P.O. Box 4428 - Santa Barbara, CA 93140-4428 - ph +(805) 684-8401 - +(805) 755-2000  