GXL14 contactor 12 to 750 Vdc / Vac  
Latching SPST EPIC® Sealed Contactor - 350+ Amp Power Switching
RoHS Compliant, all date codes
 

GXL14 contactors
Patent Pending
 
 
Contactor Features
  Latching version of GIGAVAC GX14.
  Chassis level UL508 sized power terminals – No need for specially routed power cables, special bus bars, or special lugs.
  Rugged EPIC® Seal rated to 175°C – Reduced risk of fire or meltdown in over current conditions. The same technology used for advanced aerospace programs.
  Hermetically Sealed – Designed to meet: UL1604 for Class I & II, Div 2 and Class III for use in hazardous locations, IP67 for temporary water immersion for 30 min, SAE J1171 - external ignition protection, and ISO8846 for protection against ignition around flammable gasses.
  High Efficiency Coils – Very low pull-in coil power and no hold power.
  Built-in coil suppression – Saves you engineering time and parts cost to add external coil suppression.
  Stainless steel hardware and mounting inserts, for years of corrosion free service.
  UL508 ambient compliant to 75°C but can operate continuously at 85°C with a higher terminal temperature rise of 60°C. Can also operate up to 125°C in special cases - contact GIGAVAC for details.
  Not position sensitive – can be mounted in any position for ease of installation

 

Power Switching and Current Carry Ratings

Current

Life Ratings for Given Contact Voltages Temp Rise vs Conductors (°C)
24VDC 120VDC 240VAC 300VDC 700VDC 2/0 3/0 4/0
 350A 100,000 4,000 TBD 2,000 500 75 60 50
 225A 200,000 10,000 TBD 5,000 1,000 55 45 35
 150A 300,000 20,000 TBD 10,000 2,000 40 20 12
 100A 300,000 40,000 TBD 20,000 4,000 12 8 4
 50A 300,000 100,000 TBD 50,000 8,000 5 3 2

Electrical life rating is based on resistive load with 27µH maximum inductance in circuit. Because your application may be different, we suggest you test the contactor in your circuit to verify life is as required.
 
End of life is defined as when the dielectric, insulation resistance or contact resistance exceeds the specifications listed.
  
 
At 85°C ambient, contactor can also meet all of its 75°C specifications but the terminal temperature can rise can be up to 60°C, which is higher than the 50°C rise allowed by UL508 and can be higher than some cable insulation ratings.

 

UL Compliant DC & AC Contact Current Carry Ratings
    75°C / 50°C
 Cable size 1/ KCmil 400
 Continuous, UL508 Max 1/
     10 seconds (1 time)
     100 Seconds (1 time)
     300 Seconds (1 time)
Amp
Amp
Amp
Amp
350 / 400
525 / 710
390 / 510
350 / 400
 Maximum terminal Temp, Continuous Deg C 175
 Maximum terminal Temp, Intermittent Deg C 200
1/ Assumes UL508 ratings with 400 KCmil cables, ambient max. UL508 temperature of 75°C, and max. UL508 terminal temperature rise of 50°C. Contactor can also carry the higher currents shown at 50°C ambient, and meet all of the UL508 requirements.
 
Contactor meets all of its published specifications at 85°C ambient, but terminal temperature can rise 60°C, which is higher than the 50°C allowed by UL508.
 
The maximum terminal temperature rating is 175°C, which means much higher currents can be carried and switched. However, this temperature is much higher than most cable insulation ratings, which mean busbars must be used. Contact GIGAVAC for assistance for higher current applications.

 

OPTIONAL  HIGH  EFFICIENCY  DUAL-COIL  RATINGS
 Coil Voltage (Nominal) 12Vdc 24Vdc
 Coil P/N Designation B C
 Coil Voltage (Max) 1/ 15 30
 Operate & Reset Pick-up, Current, Max - Amps 2/ 3/ 4.0 1.7
 Operate & Reset Pick-up, Volts, Max 2/ 3/ 7.5 15.0
 Coil Back EMF (volts) 4/ 45 45
Ratings are at 25ºC. For specific values at other temperatures, please contact GIGAVAC.

1/ Because the contactor is operated by a coil that changes resistance with temperature, the maximum coil voltage will be lower than indicated at temperatures above 25C, and higher than indicated at temperatures below 25C.

2/ Minimum pulse of 100ms required. Coil pulse limited to <100ms by internal electronics.

3/ Because the contactor is operated by a coil that changes resistance with temperature, Pick-up Voltage, Hold Voltage, and Drop Out Voltage will be lower than indicated at temperatures below 25C and higher than indicated at temperatures above 25C.

4/ These DC coils have built-in coil suppression.

High Voltage Relay Specifications
 Specifications Units Specifications
 Contact Arrangement (main) Form P SPST (latching)
 Contact Arrangement (Auxilary) 1/ Form A SPST (NO)
 Mechanical Life cycles 1 million
 Contact Resistance
     Max @ rated carry current
     Typical @ rated carry current
 
mohms
mohms
 
.4
.15 to .3
 Operate time, 25˚C
     Close (includes bounce) Max
     Close (includes bounce) Typical
     Make Bounce on close, Max
     Break time (includes arc time at max. break current)
 
ms
ms
ms
ms
 
20
13
7
12
 Insulation Resistance Mohms 100 2/
 Dielectric at sea level (leakage < 1mA) VRMS 2,000
 Shock G’s peak 10
 Vibration, Sinusoidal (500-2000 Hz peak) G’s 10
 Operating ambient Temp Range ˚C -55 to +85 3/
 Storage ambient Temp Range ˚C -70 to +175
 Weight, Typical Kg (Lb) 0.50/(1.1)
1/ Auxillary contact rating - 2A, 24Vdc Resistive load, 100,000 cycles. Minimum current is 100mA, 8V. The auxiliary contact is mechanically linked to the main power contacts.
 

2/ 50 Mohms after life.

3/ Contactor can operate up to 125°C in special cases - contact GIGAVAC for details.
Contactor Part Number System
GXL14 B 1 A B
 Coil Voltage
 B = 12 Vdc, internal coil suppression
 C = 24 Vdc, internal coil suppression
 High Side/Low Side Drive 
 1
= High Side
 2 = Low Side
 Coil Termination 
 A
= Flying leads, 38 cm (15 in)
 B = Flying leads, 61 cm (24 in)
 C = Flying leads, 122 cm (48 in)
 Auxiliary Contact
 Blank
= None
 B = SPST

 

gxl 14 gigavac contactor
 

Application Information:

1. WARNING - When using more than one lug on a power terminal, make sure the primary power is closest to the contactor busbar, with the lower current lug on top, then the washer, then the lock washer, then the nut. Improper order can cause severe over-heating resulting in the possible melting of the connecting cable insulation.

2. EPIC® sealing technology

3. Relay Schematics and Forms