CHANGEABLE COILS
GIGAVAC has made it easy for you to change the
coils on many of its relays, even if the relay is installed. You can change
the coils on the GIGAVAC GH, G2, G8, G15, G60 & G70 relays by following
these simple instructions. You can order replacement coils by contacting
the GIGAVAC sales office near you . If you have any questions please contact
us free of charge.
PACKAGE CONTENTS (Contact
GIGAVAC for part numbers)
1 coil
1 coil retaining plate marked with coil resistance and voltage.
1 circular spring washer.
1 coil retaining screw (GH relay) or 1 coil knurled retaining nut or all
others
REMOVE
-
Hold the relay firmly with one hand. You may want to use gloves or
a clean cloth as the oil from your skin can contribute to a high voltage
breakdown. If you need to clean the relay, use 99% isopropyl alcohol
or acetone.
-
For the GH Relays
-
For all others
Grab one of the coil terminals with your fingers
and pull out the coil.
Turn the relay over to remove the circular
spring washer. It will fall out of the coil cavity.
REPLACE
Place the new circular spring washer in the
coil cavity with the bends in the washer facing towards the coil.
Taking care that the circular spring washer
does not fall out while placing the new coil into the cavity with terminals
facing outward from the relay.
Slide the coil retaining plate over the coil
terminals. The coil terminals are not polarity sensitive so, orientation
of the plate is not important.
-
For the GH Relays
-
For all others